Mains Input
|
240/110 VAC 50/60 Hz
|
|
Performance Level
|
Complies with US Department of Justice NILECJ-0601 Standard Levels
5.
|
|
Alarm Indication
|
20 Segment LED cluster provides visual indication proportional to
amount of metal detected, audible alarm sound when level exceeds a
preset threshhold.
|
|
Resetting
|
Instant auto reset.
|
|
Sensitivity Control
|
Front panel mounted.
|
|
RFI Immunity
|
Immunce from radio frequency interference from 1 watt transmitters
at 3 metres from the detector.
|
|
Safety features
|
Does not affect heart pace-makers, magnetic media such as audio and
video tapes, watches, etc.
|
|
Anti Tamper Provisions
|
Fascia panel controls are protected by a lockable transparent door
which prevents tampering.
|
|
Throughput
|
Approximately 1 person per second can be screened, Screening
is unaffected by the velocity at which the subject enters, moves through
and leaves the detection field. (for velocities between 0.1m/sec and
3m/sec).
|
|
Remote Facility
|
Remote indication of LED column and audible alarm provided on request.
|
|
Event Counter
|
Optional event counter can be provided.
|
|
Additional Outputs
|
Outputs can be provided to operate security doors, additional alarms,
cameras and data input.
|
|
Mains Input
|
240/110 VAC 50/60 Hz
|
|
Performance Level
|
Complies with US Department of Justice NILECJ-0601 Standard Levels
5.
|
|
Alarm Indication
|
20 Segment LED cluster provides visual indication proportional to
amount of metal detected, audible alarm sound when level exceeds a
preset threshold.
|
|
Resetting
|
Instant auto reset.
|
|
Sensitivity Control
|
Front panel mounted.
|
|
RFI Immunity
|
Immune from radio frequency interference from 1 watt transmitters
at 3 metres from the detector.
|
|
Safety features
|
Does not affect heart pace-makers, magnetic media such as audio and
video tapes, watches, etc.
|
|
Anti Tamper Provisions
|
Fascia panel controls are protected by a lockable transparent door
which prevents tampering.
|
|
Throughput
|
Approximately 1 person per second can be screened, Screening
is unaffected by the velocity at which the subject enters, moves through
and leaves the detection field. (for velocities between 0.1m/sec and
3m/sec).
|
|
Battery Backup
|
Internal 24 VDC, lasts up to 4 hours, automatic cut-in, self charging.
|
|
Threshold Control
|
Audible trigger level switched by means of touchpad providing 20 steps
corresponding to the 20 step range of the LED display column. The
set level is displayed on the LCD panel.
|
|
Circuitry
|
Microprocessor control with all solid state integrated circuitry.
|
|
Self Checking
|
All circuitry is monitored by a diagnostic feature of the microprocessor
and a visual indication is given of any fault.
|
|
Remote Facility
|
Remote indication of LED column and audible alarm provided on request.
|
|
Event Counter
|
Optional event counter can be provided.
|
|
Additional Outputs
|
Outputs can be provided to operate security doors, additional alarms,
cameras and data input.
|